Sectors
Project types we review.
Every project type has its own places where the drawings, specifications, contracts, and trade scopes split. Scope and fit for each review are set in a written proposal.
Photographs are licensed from Wikimedia Commons and do not show ChangeGuard projects. Photo credits
Start with your project
Tell us the project type, the decision, when it is due, and the documents in hand.
Talk to Us About a ProjectHospitals and healthcare
Hospital projects often add an equipment planner's matrix and an infection control risk assessment to the drawings and specifications, and each describes the same work in its own terms.
Where scope commonly splits
- Owner-furnished equipment rough-ins
- The equipment planner's responsibility matrix can assign imaging and sterilizer rough-ins to the contractor while the MEP drawings and Division 11 sections mark them by owner or leave them out.
- Medical gas outlets and zone valves
- Outlet counts on the headwall elevations and room data sheets can differ from the medical gas piping plans, and the zone valves on the plans from the zone valve box schedule.
- Infection-control barriers and phasing
- The infection control risk assessment can call for anterooms, hard barriers, and HEPA-filtered negative air that the phasing drawings and trade scope sheets do not carry.
Life sciences and labs
In lab buildings, the lab planner's furnish scope meets the MEP design at fume hoods, casework, and service fittings, where responsibility changes hands.
Where scope commonly splits
- Fume hood monitors and airflow controls
- The fume hood section can have the hood manufacturer furnish airflow monitors and sash sensors while the mechanical drawings and controls sequence assign them to the controls contractor.
- Service fitting final connections
- The laboratory casework section can have the casework supplier furnish and mount service fittings while the plumbing and process piping drawings and the plumbing scope sheet leave final connections unassigned.
- Owner-furnished lab equipment utilities
- The lab planner's equipment matrix can list hard-ducted biosafety cabinets and autoclave steam and drains while the mechanical and plumbing drawings show canopy exhaust or leave the connections out.
Industrial and manufacturing
Manufacturing buildings carry two designs at once, building and process, and the scope line between them is drawn in different documents by different engineers.
Where scope commonly splits
- Process utility tie-in points
- The process P&IDs and tie-in list can set battery limits for compressed air, process water, and exhaust at tie-in points the building mechanical and plumbing drawings place elsewhere or leave out.
- Equipment pads, pits, and anchor bolts
- Certified vendor drawings and foundation load data can call for pads, pits, and anchor bolts that the structural foundation plans and concrete scope sheet leave out or size for an earlier equipment selection.
- Setting owner-furnished process equipment
- The owner's equipment responsibility matrix can assign rigging, setting, grouting, and power connections to the contractor while the electrical drawings and millwright scope sheet leave them to the vendor.
Athletic and sports venues
Venues bring specialty vendors for scoreboards, sports lighting, and seating into a base-building design that has to carry their weight, power, and data.
Where scope commonly splits
- Video board steel, power, and fiber
- The video board specification can assign support steel, power, and fiber pathways to the base building while the structural, electrical, and low-voltage drawings mark them by the board vendor.
- Sports lighting poles, bases, and controls
- The sports lighting specification can have the vendor furnish poles, precast bases, and control cabinets that the site electrical plans and foundation details also carry as trade work.
- Seating layout and riser geometry
- The seating manufacturer's layout and anchorage details can call for seat counts, wheelchair spaces, tread depths, and embeds that the architectural seating plans and precast riser drawings show differently.
Multifamily and mixed-use
Multifamily sets repeat unit types across many floors, so a mismatch between plans, schedules, and assembly details repeats wherever that unit or wall type does.
Where scope commonly splits
- Unit plans against appliance schedules
- Enlarged unit plans can show appliances, sinks, and washer-dryer locations that the appliance schedule and unit matrix assign to a different unit type or leave out.
- Plumbing stacks at the podium transfer
- The plumbing plans can offset stacks at the podium where the transfer slab's post-tensioning layout and penetration details make no allowance for them, and the architectural sections align the walls above differently.
- Rated and acoustic partition types
- The partition type schedule can carry fire ratings and STC values that the life safety plans, rated assembly details, and gypsum board specification section describe differently.
Commercial office and interiors
Interior fit-outs sit inside someone else's building, so the lease, the landlord's rules, and the tenant drawings each claim part of the scope.
Where scope commonly splits
- Landlord work versus tenant work
- The landlord work letter can assign ceiling grid, restroom upgrades, and sprinkler head relocation to the landlord while the tenant drawings and bid form carry them as tenant work.
- Landlord-required fire alarm and building controls vendors
- The tenant electrical and mechanical drawings and scope sheets can carry fire alarm and building controls work while the landlord's building rules require the building's designated vendors for those systems.
- Furniture and AV vendor requirements
- Furniture and AV vendor layouts can call for power feeds and data drops the tenant electrical plans and low-voltage scope sheet do not show, and in-wall display blocking the interior elevations and framing scope sheet do not carry.
K-12 and higher education
School and campus projects often add owner standards, a formal bid form, and calendar-driven phasing to the drawings and specifications, and the owner's documents may not agree with the design team's.
Where scope commonly splits
- Owner standards versus project specifications
- District or campus design standards can name keying, building automation, and fire alarm manufacturers that the project specification sections list differently or open to substitution.
- Bid-form alternate boundaries
- The bid form can describe add and deduct alternates whose limits the Division 01 alternates section and the alternate notes on the drawings draw in different places.
- Work windows around the academic calendar
- Summer and break-period work windows in the Division 01 phasing requirements can differ from the phasing drawings' area sequence and the work hours assumed in trade scope sheets.
Data centers and mission-critical facilities
Data center owners often buy generators, switchgear, and cooling units directly, so vendor scope, trade scope, and commissioning scope meet at the owner-purchased equipment.
Where scope commonly splits
- Setting and starting owner-purchased gear
- Owner purchase orders and the equipment responsibility matrix can end vendor scope at delivery while the electrical specification has the vendor rig, set, and start up generators and switchgear.
- Load banks, fuel, and integrated testing
- The commissioning plan can assign load banks, test fuel, and integrated systems testing support to the contractor while the generator specification section assigns them to the vendor or owner.
- Vendor data against one-lines and piping
- Vendor data for owner-purchased switchgear and cooling units can show breaker sizes, lug configurations, and piping connections that differ from the one-line diagram, feeder schedule, and mechanical piping drawings.
Working on another project type?
Tell us what you are working on, and we will say plainly whether it fits.
Photo credits
Each picture on this page and on the home page is a photograph from Wikimedia Commons, and each credit says how we changed it. None shows a ChangeGuard project.
- Hospitals and healthcare Photo by Anastasia Puscian, U.S. Navy, public domain, via Wikimedia Commons. Cropped, resized, exposure lifted slightly, and a small maker's mark softened.
- Life sciences and labs “Lab bench” by Magnus Manske, CC BY 1.0, via Wikimedia Commons. Cropped, resized, and a small maker's mark softened.
- Industrial and manufacturing “Industrial production line operating in a large modern factory” by Shixart1985, CC BY 2.0, via Wikimedia Commons. Cropped and resized.
- Athletic and sports venues Photo by Mattes, public domain, via Wikimedia Commons. Cropped and resized.
- Multifamily and mixed-use “25 Wood frame condominium construction in Canada - apartment building construction in Fernie, British Columbia” by Marek Ślusarczyk (Tupungato), CC BY 3.0, via Wikimedia Commons. Cropped and resized.
- Commercial office and interiors Photo by Loominade, CC0 1.0, via Wikimedia Commons. Cropped and resized.
- K-12 and higher education “Elementary school classroom in Vantaankoski school in Vantaa, Finland, 2010” by Leo-setä, CC BY 2.0, via Wikimedia Commons. Cropped and resized.
- Data centers and mission-critical facilities “Summit Computer Room Installation (rubin-2018-05-02-192415)” by Rubin Observatory/NSF/AURA, CC BY 4.0, via Wikimedia Commons. Cropped, resized, and exposure lifted slightly.